Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen

    Buy cheap Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen from wholesalers
     
    Buy cheap Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen from wholesalers
    • Buy cheap Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen from wholesalers
    • Buy cheap Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen from wholesalers
    • Buy cheap Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen from wholesalers
    • Buy cheap Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen from wholesalers
    • Buy cheap Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen from wholesalers
    • Buy cheap Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen from wholesalers

    Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen

    Ask Lasest Price
    Brand Name : BIO
    Model Number : PM-9000A+
    Price :
    Payment Terms : Credit card, Paypal, T/T
    Delivery Time : 7 working days at sight of payment
    Supply Ability : 1000 units / month
    • Product Details
    • Company Profile

    Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen

    conomical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen


    ​Features


    1Brand-new high-precision module, with high measurement parameter accuracy, reliable quality and stable performance.
    2Rotary shuttle operation mode, Chinese and English logo buttons, easy to learn and use, simple and intuitive operation.
    3High-brightness and high-resolution 12.1-inch color TFT LCD display.
    4Three-channel ECG waveform, seven-channel simultaneous display of ECG in all leads.
    5Multiple display interfaces: single-lead, standard, large font, full-lead, and trend charts coexist.
    6The new aluminum alloy internal structure design has good shock resistance and meets the use of mobile environments.
    7The new digital blood oxygen technology is adopted to make the measurement of weak perfusion and finger shaking more accurate.
    8ST segment automatic detection, arrhythmia analysis, drug concentration drop table analysis.
    9The new fully-isolated floating design is resistant to defibrillation and high-frequency electrosurgical interference, and is suitable for use in harsh environments such as operating rooms and wards.
    10NIBP dual overvoltage protection temperature drift control and other technologies ensure accurate measurement and protect patient safety.
    11Powerful storage capacity, full parameter trend chart data throughout the whole process, ECG waveform storage and playback, and power-down save function.
    12Automatic sound and light dual alarm, the upper and lower alarm limits can be set arbitrarily.
    13Fanless design, dust-free, low power consumption, and improve the service life of the instrument.
    14The body is light and firm, easy to carry, suitable for adults, children and newborns.
    15Support wired and wireless networking functions, and support software online upgrades.
    16Optional built-in removable rechargeable lithium battery, AC and DC dual purpose, light, energy saving and environmental protection.
    17Optional built-in dual-channel thermal array recorder, real-time printing of waveforms and icons.
    18It is widely used in bedside monitoring, ICU/CCU, emergency center, family monitoring, etc. in various departments of the hospital.
    19Optional wall bracket, mobile bracket, and medical backpack.

    Standard Configuration


    1PM-9000A+ multi-parameter monitor host1 unit
    2standard five-lead ECG lead connection cable1 set
    3standard adult blood pressure cuff1 set
    4adult blood oxygen probe1 set
    5temperature probe1 set
    6power plug cord1 set
    7ground wire1 set
    8User's manual1 set

    Optional Configuration


    1Built-in rechargeable lithium battery
    2Dual-channel thermal printer
    3Monitor cart/bracket/hanger
    4Wrapped blood oxygen probe for children or newborns
    5Blood pressure cuffs for children or newborns

    Specification


    1ECGLead selection: full lead, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest lead display
    Gain selection: ×1, ×2, ×0.25, ×0.5 four gears
    Frequency: 0.5Hz—100Hz
    Common mode signal rejection: greater than 70dB
    Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files
    Heart rate accuracy: ±5 beats/minute
    Calibration signal: 1mV (peak value, accuracy ±3%)
    ST segment detection: measuring range (-2.0mV---+2.0mV)
    Use standard: in line with ANSI/AMI EC13-2002 standard
    Response time: 1S
    Alarm mode: sound and light alarm
    Heart rate alarm preset range: (exceed the preset value alarm)
    The upper limit is adjustable between 1-255 times/minute
    The lower limit is adjustable between 0-254 times/minute
    2NIBP
    Technology: Oscillographic Method
    Measurement method: reverse measurement data is more accurate
    Unit of measurement: mmHg/Kpa
    Overvoltage protection: double safety protection
    One measurement time: less than 45S
    Pressure range in cuff: 0-250mmHg
    Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value
    Initial inflation of cuff: 180mmHg (120mmHg for children)
    Cuff subsequent inflation: original systolic blood pressure + 30mmHg
    Blood pressure measurement range and error:
    Systolic blood pressure 60 mmHg~250 mmHg
    Average pressure 45 mmHg~235 mmHg
    Diastolic blood pressure 40 mmHg~220 mmHg
    Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater
    Response time: 1S
    Alarm mode: sound and light alarm
    Alarm prediction range and error: (Alarm when exceeding the preset value)
    Systolic blood pressure upper limit 1mmHg~255 mmHg
    ​Lower limit 0 mmHg ~255 mmHg
    Diastolic blood pressure upper limit 1mmHg~255 mmHg
    Lower limit 0 mmHg~254 mmHg
    Alarm error: ±1 mmHg
    Use standard: in line with ANSI/AAMI SP10-2002 standard
    3SPO2Range: 0-100%
    Accuracy: 1%
    Resolution: 1%
    Pulse frequency: 20-250 beats/min
    Response time: 1S
    Alarm mode: sound and light alarm
    Alarm range and error: (Alarm exceeding the preset value)
    Upper limit 1%~100%
    Lower limit 0%~99%
    4TEMPTechnology: Highly sensitive thermistor probe
    Body temperature measurement range: 20℃-- 45℃
    Resolution: 0.1%
    Body temperature accuracy: ±1℃
    Response time: 1S
    Alarm mode: sound and light alarm
    Alarm preset range and error: (Alarm when exceeding the preset value)
    The upper limit is adjustable between 20.1℃-- 45.5℃
    The lower limit is adjustable between 20℃ and 45.4℃
    Alarm error: ±1℃
    5RESPRespiration rate range: 0-60 times/min
    Accuracy: ±1rpm
    Response time: 1S
    Gain options: ×1, ×2, ×4, ×0.5 four gears
    Alarm mode: sound and light alarm
    Alarm preset range and error: (Alarm when exceeding the preset value)
    The upper limit is adjustable between 10-100 times/minute
    The upper limit is adjustable between 0-99 times/minute
    Alarm error: ±1rpm
    6Printer(Optonal)Specifications: Dual-channel thermal array recorder
    Printing method: real-time or event trigger recording waveform, text
    Resolution: Horizontal: 400dpi / Vertical: 800dpi
    Note: Date (year/month/day)/time (24 hours)
    Optional wall bracket, mobile bracket, backpack
    7SystemDisplay: 12.1 inch TFT true color LCD display
    Safety standard: lec601-1 (International GB9706.1)


    Quality Economical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen for sale